Part Number 80-1505-3 6/11 181
IB Model Ice Machines
Before Serial Number 050400000
FUNCTION
The switch is used to place the ice machine in ICE,
OFF or CLEAN mode of operation.
SPECIFICATIONS
Double-pole, double-throw switch. The switch is
connected into a varying low D.C. voltage circuit.
CHECK PROCEDURE
NOTE: Because of a wide variation in D.C. voltage, it
is not recommended that a voltmeter be used to check
toggle switch operation.
1. Inspect the toggle switch for correct wiring.
2. Isolate the toggle switch by disconnecting all
wires from the switch, or by disconnecting the
Molex connector and removing wire #69 from the
toggle switch.
3. Check across the toggle switch terminals using a
calibrated ohmmeter. Note where the wire
numbers are connected to the switch terminals, or
refer to the wiring diagram to take proper
readings.
4. Replace the toggle switch if ohm readings do not
match all three switch settings.
Switch
Setting
Terminals Ohm Reading
ICE
66-62 Open
67-68 Closed
67-69 Open
CLEAN
66-62 Closed
67-68 Open
67-69 Closed
OFF
66-62 Open
67-68 Open
67-69 Open