EasyManuals Logo
Home>Manitowoc>Ice Maker>QuietQube SD1072C

Manitowoc QuietQube SD1072C User Manual

Manitowoc QuietQube SD1072C
298 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #203 background imageLoading...
Page #203 background image
Part Number 80-1505-3 6/11 203
PTCR Operation Check
1. Visually inspect the PTCR. Check for signs of
physical damage.
NOTE: The PTCR case temperature may reach
210°F (100°C) while the compressor is running. This is
normal. Do not change a PTCR just because it is hot.
2. Wait at least 10 minutes for the PTCR to cool to
room temperature.
3. Remove the PTCR from the ice machine.
4. Measure the resistance of the PTCR as shown. At
room temperature the resistance reading must be
between 8 & 22 ohms.
.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc QuietQube SD1072C and is the answer not in the manual?

Manitowoc QuietQube SD1072C Specifications

General IconGeneral
BrandManitowoc
ModelQuietQube SD1072C
CategoryIce Maker
LanguageEnglish

Related product manuals