EasyManuals Logo
Home>Manitowoc>Ice Maker>RFS1200

Manitowoc RFS1200 User Manual

Manitowoc RFS1200
284 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
22 Part Number 000007661 11/16
Potable Water Requirements
Plumbing must conform to local codes.
Water temperature: Minimum 40°F (4°C), Maximum
90°F (32°C).
Do not connect the ice machine to a hot water
supply. Be sure all hot water restrictors installed for
other equipment are working. (Check valves on sink
faucets, dishwashers, etc.)
If water pressure exceeds maximum pressure (70
psig [483 kPa] RN1000; 80 psig [552 kPa] for all other
models) obtain a water pressure regulator from your
Manitowoc distributor.
A water shut-off valve is required to clean the ice
machine.
A union for both the ice making and condenser water
lines is required.
Water inlet lines require insulation to prevent
condensation.
RF/RFS/RFN Models: A back flow preventer is required
on water inlet lines.
Drain Connections
Drain lines must have a 1.5 inch drop per 5 feet of run
(2.5 cm per meter), and must not create traps.
The floor drain must be large enough to
accommodate drainage from all drains.
Bin drain termination must have an air gap.
Separate insulated bin and water-cooled condenser
drain lines are required.
The bin and ice machine drains require a vent.