Part Number: 040006977 Rev. 01 03/19 17
General
The end user is responsible for maintaining the ice machine
in accordance with the instructions in this manual.
Maintenance procedures are not covered by the warranty.
,
Caution
If you do not understand the procedures or the safety
precautions that must be followed, call your local service
representative to perform the necessary maintenance
procedures for you.
Maintenance Weekly Monthly Semi Annual Annual
After prolonged
shutdown
At Start-up
Clean cabinet exterior X X X
Sanitize Ice Bin X X X
Clean Evaporator X S S
Sanitize Evaporator X S S S
Clean Condenser Coil X S S
Check Ice Quality X S S S
X= End User
S=Service Company
Basic hygiene and maintenance of your Ice Machine, will
increase its reliability, increase performance, and help
save on water and power consumption. Ice production
will be maintained within the manufacturers guidelines,
and unwanted repairs due to maintenance issues will be
minimized.
The chart below is an overview of the maintenance that
the end user and service technician should perform, and
the frequency. These figures are the minimum required. If
the Ice Machine is supplied with hard water, more frequent
evaporator cleaning should be performed. If the condenser
air filter is totally blocked, after one week, more frequent
cleaning is recommended.
Section 4
Maintenance

Other manuals for Manitowoc Sotto UG-40

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Sotto UG-40 and is the answer not in the manual?

Manitowoc Sotto UG-40 Specifications

General IconGeneral
BrandManitowoc
ModelSotto UG-40
CategoryIce Maker
LanguageEnglish

Related product manuals