EasyManuals Logo
Home>Marey>Water Heater>GA16ETL

Marey GA16ETL User Manual

Marey GA16ETL
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
3332
CLEARANCE REQUIREMENTS
ADJACENT MATERIAL COMPOSITION
NON-COMBUSTIBLE COMBUSTIBLE
SIDE: 2 inches (50 mm) 2 inches (50 mm)
TOP: 2 inches (50 mm) 6 inches (300 mm)
FLOOR: 12 inches (300 mm) 12 inches (300 mm)
FRONT: 24 inches (600 mm) 24 inches(600 mm)
BACK: zero (zero) 1 inch (25 mm) fireproof
Insulating panel required.
- Ventilation requirements must be considered when choosing installation location.
- Minimizing vent piping will reduce installation costs and maximize efficiency. We
recommend that a service valve kit be used for the installation as it will reduce
installation costs and make servicing the water heater easier. The Webstone
44043PR or similar service valve kit. These kits include the Service Valves, Unions,
Ball Valves and Temperature / Pressure relief valves specified in the Typical
Installation Figure above in one convenient easy to install kit.
The heater MUST be installed in a vertical position with fuel gas inlet
at the bottom and exhaust vent positioned at the top. Installation in
any other orientation will result in damage and will void warranty.
1. Identify a suitable location per the “Location and Clearance Guidelines”. Ensure
that the heater will be attached in a manner that is sufficient to support the weight of
the heater in operation.
2. The system should only be mounted on a fire rated wall or piece of fire rated board
that is mounted with spacers 1/3in (10mm) off the wall and protrudes at least 4in
(100mm) beyond the sides of the water heater will have to be mounted. (Check with
local codes).
LOCATION
Choose a location for unit installation taking into account the following guidelines.
- Unit must be installed indoors. Installation is not recommended in bathrooms,
bedrooms or occupied rooms that are normally kept closed.
- Unit should have proper clearance as indicated below including ample clearance in
front of unit for proper service access.
Installation is recommended to be at a height that will allow easy viewing and
operation of the control panel.
- Heater requires a standard three prong, 120 V /60 Hz grounded AC power outlet
within 5 feet (1.6 meters) of installation location.
- Heater requires a ½” gas supply line (12mm).