12
4.8 AUTO CALIBRATION PROCEDURE
AUTO CALIBRATION PROCEDURE
After initial installation or after installing a new lift motor, Auto Calibration must be run. This will synchronize the 2
lift motors to ensure the unit elevates evenly.
1) Press ENTER 3, 0, 0, 1, ENTER and the unit will go into Service Mode.
2) Press the button next to TEST on the display.
3) Press the button next to AUTO CALIBRATION on the display.
4) This will run the Auto Calibration. If the calibration passes, it will say Complete. Press and hold the STOP key to return to normal function.
5) If the auto calibration fails, contact the Matrix Technical Support Team.
CHAPTER 4: CONSOLE OVERLAY AND WORKOUT DESCRIPTION