33
8.3 CONSOLE ERROR CODES
CHAPTER 8: TROUBLESHOOTING
CODE DESCRIPTION SOLUTION
0x0140 When the UCB implements an incline command, there is no
movement after 3 seconds.
Replace the LCB or Incline Motor.
0x0142 Theinclinepositionhasadifferenceofover3%andisnotreduced
within 3 seconds.
Look for misalignment of the Incline
Motors, replace if needed.
0x0441 When the UCB implements a command, the LCB is not receiving. Check the console cable connections,
replace the LCB or UCB as needed.
0x01A0 Incline motor disconnected. Check the connection of the incline
motor cables at the LCB. Replace the
incline motors or LCB as needed.
0x01A1 Incline calibration is over 80 seconds or does not complete. Replace the LCB or Incline Motor
0x01A7 The incline is short circuited or over current. Look for misalignment of the Incline
Motors, replace if needed.
0x01AC ECB has an open circuit, short circuit, or the current is over 2.3
Amps for 1.4 seconds.
Replace the ECB.
0x01AE The battery charge is over current or short circuited. Replace the battery.
0x01AF Resistance or solenoid circuit. Check the generator and resistor.
0x02AB Machine type error. Set the console for Ascent Trainer.
0x02B3 Resistance type error. Check the amperage of the ECB,
replace if needed. If ok, replace the
LCB.
0x02B4 Resistance Type Error Verify that the LCB and UCB software
versions are correct.
Replace the LCB if needed.
0x03A5 Failed to Load Program. Usually means that the file is corrupt.
The software should be re-loaded, or if
necessary the console can be replaced.
0x03A6 Failed to Run Program. Usually means that the file is corrupt.
The software should be re-loaded, or if
necessary the console can be replaced.
0x04A0 If the LCB does not return a message to the UCB within 3 seconds. Check the console cable connections,
replace the LCB or UCB as needed.
0x04B0 UCB no communication response. Check the connection of the console
cable at the UCB and LCB. Replace
the console cable, UCB, or LCB as
needed.