Technical Information
33
VA
1
offee
stem
4.15 Flow meter
All water taken from the water container flows through the flow
meter. The flow meter passes signals to the electronic unit
proportional to the quantity of water passing through it.
The electronic unit then establishes the quantity of water that has
flowed and stores the figure. Approx. 300 pulses from the flow
meter indicate a flow of 100 ml water.
The electronic unit controls the required water quantity for beverage
preparation and ensures that it remains constant. The service mode
can be used to check the proper operation of the flow meter.
4.16 Heater - Data
Coffee / Hot Water Heater 1R1 & 1R2
Voltage 220(240) V
Power rating 1090 W / 437 W
Steam Heater 2R1
Voltage 220(240) V
Power rating 1100 W