Powered by TCPDF (www.tcpdf.org)
MUW216743-2 25
Problem Cause and remedy
Spray arm monitoring -
upper wash cabinet: Spray
arm blocked or excessive
foaming
or
Spray arm monitoring -
lower wash cabinet: Spray
arm blocked or excessive
foaming
or
Spray arm monitoring
- mobile unit spray arm
1:
Spray arm blocked or
excessive foaming
The rotation speed set has not been reached because:
• Items are obstructing the machine or basket spray arms. Arrange the load so that the
spray arms can turn easily and start the programme again.
• The relevant spray arm nozzles are blocked. Clean the spray arm. Check whether the
lters in the wash cabinet are clean and correctly inserted.
• Start the programme again - wash pressure is too low due to a heavy build-up of foam.
• Follow the instructions regarding foam build-up below.
Foam build-up If there is foam in the wash cabinet, physically remove it into a container and run a RINSE
cycle.
Foaming can be caused by foam-inducing pre-treatments that have not been rinsed from the
cabinet, or by excessive dosing of chemicals.
Spray pressure exceeds
tolerance
The spray pressure has deviated by more than 20% from the mean value.
Reasons for uctuations in wash pressure are e.g.:
• Defective water connections,
• Open adapters,
• Foam build-up.
Identify and resolve the cause of this. The programme was not interrupted, however the
wash load must be reprocessed again.
Problem Cause and remedy
Check water inlet • One or more stopcocks are closed. Open the stopcocks.
• There was insucient water in the machine. Clean the water intake lters. Open the
stopcocks fully.
• Flow pressure at the water connection is less than 0.3bar (30kPa). Contact a suitably
qualied plumber as the water pressure is too low.
Check drainage
The water drains away slowly or cannot drain away:
• The drain hose is blocked. Remove any kinks or large loops in the drain hose. Start the
programme again.
• The lters in the wash cabinet are blocked. Clean the lters in the wash cabinet.
Protective measures for personal safety must be observed. Start the programme again.
• The drain pump or non-return valve may be blocked. Clean the access to the drain
pumps and the non-return valve. Protective measures for personal safety must be
observed. Start the programme again.
• The drainage system cannot take sucient water. Contact a suitably qualied plumber.
6.9. Water Inlet & Drainage
6.8. Spray Arm Monitoring/Wash Pressure