EasyManuals Logo

Mitsubishi Heavy Industries L-Series User Manual

Mitsubishi Heavy Industries L-Series
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #66 background imageLoading...
Page #66 background image
8-11
Chapter 8 PERIODIC INSPECTION AND MAINTENANCE PROCEDURES
Cooling system - Clean
1. Close coolant drain cocks and plugs.
2. Pour in a cleaning solution (a solution that is non-
corrosive to rubber and metals) in the cooling sys-
tem, and operate the engine at 800 to 900 min
-1
for
about 15 minutes, then drain the cleaning solution.
3. Close coolant drain cocks and plugs.
4. Pour in fresh water, and operate the engine at 800
to 900 min
-1
for about 10 minutes.
Repeat rinsing until the draining water becomes
clear and clean.
Fig. 8-17 Coolant drain plug (engine)
Clean the cooling system when operating the engine
first time, or restarting the engine after storage with
coolant drained.
Coolant drain plug

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries L-Series and is the answer not in the manual?

Mitsubishi Heavy Industries L-Series Specifications

General IconGeneral
BrandMitsubishi Heavy Industries
ModelL-Series
CategoryEngine
LanguageEnglish

Related product manuals