4.6 SLEEP operation:
(1) SLEEP operation: This function prevents the temperature in the cooling operation from
becoming too low and the temperature in the heating operation from
becoming too high; regulates the room temperature automatically as
time goes by; and stops automatically after the time set.
(2) Operation method:
If the SLEEP button is pressed during the operation of the air
conditioner, and the run time, such as , will appear.
There are 11 options, including 1-10 hours (interval of 10 hours)
and OFF.
If the SLEEP button is pressed when the air conditioner is in the
stop mode, the air conditioner will execute the previous
operation settings and stop after the time set.
(3) Making correction based on the set temperature and regulating the
room temperature automatically:
During cooling operation:
Beginning (-1), 1 hour later (±0), 2 hours later (+1);
During heating operation:
Beginning (-1), 30 minutes later (-2), 1 hour later (-1), 2 hours later (-6); 4 hours
later (-3)
(4) The set time of SLEEP operation can be changed with the SLEEP button at any time. Since
the remote controller receives the change signal, the air conditioner continues to run
according to the changed set time.
(5) When the operation switch change signal is received during the SLEEP operation, the air
conditioner will control the sleep setting according to the operation switching and the
temperature correction value in the elapsed time will be retained.
(6) When the set temperature change signal is received during the SLEEP operation, the
temperature correction value will be recalculated.
(7) When the air conditioner is set to automatic control (fuzzy automatic) and the indoor
operating mode (cool room · drying · warm room) is set, the SLEEP operation begins. The
change of cool room · drying · warm room state arising from the automatic control (fuzzy
automatic) is made only when the set temperature is changed. (In other words, the operating
mode judgment according to the operation judgment timing is not executed.)
(8) Priority of sleep timing operation
Set temperature correction: HI POWER operation > Setting correction temperature
Timing: Sleep timing run > HI POWER run
4.7 Timing OFF:
(1) Timing OFF: The timing OFF operation begins when the Timing OFF
signal is received from the remote controller and stops after the set time.
(2) Operation method:
When the air conditioner is in the stop mode, press the ON/OFF
button;
When the air conditioner is running, press the TIMER OFF button
and the Timing OFF indicator will flash;
Press the or button to set the OFF time (unit: 10
minutes);
Within 60 seconds, press the TIMER OFF button and the indicator
will change from flashing to a fixed state. The setting is finished;
The TIMER lamp (yellow) of the indoor unit lights up.
(3) Use the TIMER OFF button to set a new Timing OFF time at any time.
(4) During the Timing OFF operation, all setting change signals from the remote controller are
accepted.
(5) During the Timing OFF operation, when the Timing ON signal is received, the operation will
become the programmed timing operation and the remaining Timing OFF time will be
retained.
(6) During the Timing OFF operation, when the Sleep signal is received, the Timing OFF
operation will be canceled (and the remaining time will be canceled too) and the operation
will be switched to the SLEEP operation. (In other words, the SLEEP operation can’t be used
with the Timing OFF function.)
(7) To cancel the Timing OFF function, press the Cancel button and the TIMER lamp will go
off.
Sleep
timing
Timing
OFF

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries SRC25MA-S and is the answer not in the manual?

Mitsubishi Heavy Industries SRC25MA-S Specifications

General IconGeneral
BrandMitsubishi Heavy Industries
ModelSRC25MA-S
CategoryAir Conditioner
LanguageEnglish

Related product manuals