- 6 -
2.2 Range of usage
Please use the air conditioners within the following range of usage, otherwise the protector will be
triggered.
Cooling Operation
Heating Operation
Outdoor temperature
About 18~43
About -15~24
Indoor temperature
About18~32
About below 30
Indoor humidity
About below 80%
20~50 Models
Max. piping one-way length
Within 15 m
Vertical height difference
Within 5 m
Additional R410A Refrigerant
Not required
Voltage
Rating ±10%
Starting voltage
At least 85% of rating
Switching frequency
Max. 10 times per hour
Time interval between stop and start
Min. 3 min
2.3 Outline drawing
(1) Indoor unit: MA-S Series Unit: mm