2.1.2 SELECTION DATA
(1) Specifications
Model SRK10CES (Indoor unit)
SRC10CES (Outdoor unit)
(2) The operation data are applied to the 220 V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 7.5 m connecting piping.
(Purging is not required even in the short piping.)
If the piping length is longer, when it is less than 10 m, add 10 g refrigerant per meter and when it is 10 to 15 m, add 30 g refrigerant per meter.
(4) Expressed in sound pressure level.
Notes (1) The data are measured at the following conditions.
Item
Model
SRK10CES SRC10CES
Cooling capacity
(1)
W 2700
Power source 1 Phase, 220V, 50Hz
Cooling input kW 0.803
Running current (Cooling) A 4.2
Inrush current A 18.1
COP (In cooling) 3.36
Noise level
(4)
dB 39 46
Exterior dimensions
mm 250 × 815 × 249 540 × 720 × 290
Height × Width × Depth
Color Cool white Stucco white
Net weight kg 10.5 34
Refrigerant equipment
–
RMC201A002
Compressor types & Q’ty
Motor kW – 0.75
Starting method – Line starting
Heat exchanger Louver fins & tubing
Refrigerant control Capillary tubes
Refrigerant
(3)
kg R22 0.75 (Pre-Charged up to the piping length of 7.5m)
Refrigerant oil R 0.35 (ATMOS M60 or SUNISO 4GDID)
Air handling equipment
Tangential fan × 1 Propeller fan × 1
Fan type & Q’ty
Motor W 14 15
Air flow (at High) CMM 8.5 30.0
Air filter, Q’ty Polypropylene net (washable) × 2 –
Shock & vibration absorber – Cushion rubber (for compressor)
Electric heater ––
Operation control
Wireless-Remote control –
Operation switch
Room temperature control Microcomputer thermostat –
Pilot lamp RUN (Green), TIMER (Yellow),
–
HI POWER (Green), ECONO (Orange)
Safety equipment Frost protection,
Compressor overheat protection
Fan motor error protection
O.D mm (in) Liquid line: ø6.35 (1/4") Gas line: ø9.52 (3/8")
Connecting method Flare connecting
Attached length of piping Liquid line: 0.4 m
–
Gas line : 0.33 m
Insulation Necessary (Both sides)
Drain hose Connectable
Power source cord 2.5 m (3 cores with Earth)
Size × Core number 1.5 mm
2
× 3 cores (Including earth cable)
Connecting method Terminal block (Screw fixing type)
Accessories (included) Mounting kit
Optional parts –
Connection
wiring
Operation
data
(1)
Refrigerant
piping
Item Indoor air temperature Outdoor air temperature
Standards
Operation DB WB DB WB
Cooling 27°C19°C35°C24°C ISO-T1, JIS C9612