4
-
Item
Model
SRK13ZEV-S SRC13ZEV-S
Cooling capacity
(1)
W 4000 (400~5000)
Heating capacity
(1)
W 6000 (400~9000)
Power source 1 Phase, 220V, 50Hz
Cooling input kW 0.93 (0.105~1.5)
Running current (Cooling) A 5.5
Heating input kW 1.38 (0.095~2.490)
Running current (Heating) A 6.8
Inrush current A 6.8
COP Cooling: 4.30 Heating: 4.35
Noise level
Cooling Sound level 46 47
Heating
Sound level 46 47
Exterior dimensions
Height × Width × Depth
mm
298 × 840 × 259 595 × 780 × 290
Color Cool white Stucco white
Net weight kg 12 39
Refrigerant equipment
Compressor type & Q’ty
– 5CS102XFA (Scroll type) × 1
Motor kW – 1.1
Starting method – Line starting
Heat exchanger Louver fins & inner grooved tubing Straight fins & inner grooved tubing
Refrigerant control Capillary tubes + Electronic expansion valve
Refrigerant
(3)
kg R410A 1.35 (Pre-Charged up to the piping length of 15m)
Refrigerant oil R 0.36 (RB68A)
Deice control Microcomputer control
Air handling equipment
Fan type & Q’ty
Tangential fan × 1 Propeller fan × 1
Motor W 33 34
(Cooling)
Air flow (at High)
(Heating)
CMM
Air filter, Q’ty Polypropylene net (washable) × 2 –
Shock & vibration absorber – Cushion rubber (for compressor)
Electric heater ––
Operation control
Operation switch
Wireless-Remote control –
Room temperature control Microcomputer thermostat –
Pilot light RUN (Green), TIMER (Yellow), JET/HI POWER (Green), ION (Green)
Safety equipment
O.D mm (in) Liquid line: φ6.35 (1/4″) Gas line: φ9.52 (3/8″)
Connecting method Flare connecting
Attached length of piping Liquid line: 0.54 m
Gas line : 0.47 m
–
Insulation Necessary (Both sides)
Drain hose Connectable
Power source cord 2 m (3 cores with Earth)
Size × Core number 1.5 mm
2
× 4 cores (Including earth cable)
Connection wiring
Connecting method Terminal block (Screw fixing type)
Accessories (included) Mounting kit, Clean filter (Allergen clear filter × 1, Natural enzyme filter × 1)
Optional parts –
Notes (1) The data are measured at the following conditions.
1.1.2 SELECTION DATA
(1) Specifications
Model SRK13ZEV-S (Indoor unit)
SRC13ZEV-S (Outdoor unit)
Item Indoor air temperature Outdoor air temperature
Standards
Operation DB WB DB WB
Cooling 27ºC19ºC35ºC24ºC ISO-T1, JIS C9612
Heating 20ºC – 7ºC6ºC ISO-T1, JIS C9612
(2) The operation data are applied to the 220V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 15 m connecting piping.
(Purging is not required even for the short piping.)
If the piping length is longer, when it is 15 to 25 m, add 20 g refrigerant per meter.
Operation data
(1)
Refrigerant
piping
Compressor overheat protection, Heating overload protection (High pressure control), Overcurrent protection,
Frost protection, Serial signal error protection, Indoor fan motor error protection, Cooling overload protection
The piping length is 7.5m.
(220V)