Item
Model
SRK19CES SRC19CES
Cooling capacity
(1)
W 5600
Power source 1 Phase, 220V, 50Hz
Cooling input kW 1.63
Running current (Cooling) A 8.1
Inrush current A 42
COP Cooling: 3.44
Cooling
Sound level Hi 45, Me 41, Lo 38 49
Noise level
Power level
dB
60 65
Exterior dimensions
Height × Width × Depth
mm
318 × 1098 × 248 640 × 850 × 290
Color Yellowish white Stucco white
Net weight kg 15 46
Refrigerant equipment
Compressor type & Q’ty
RM5522GNE4 (Rotary type) × 1
Motor kW 1.7
Starting method Line starting
Heat exchanger Slit fins & inner grooved tubing Straight fin & inner grooved tubing
Refrigerant control Capillary tubes + Electric expansion valve
Refrigerant
(3)
kg R22 1.3 (Pre-Charged up to the piping length of 15m)
Refrigerant oil R 0.7 (BARREL FREEZ 32SAM)
Deice control Microcomputer control
Air handling equipment
Fan type & Q’ty
Tangential fan × 1 Propeller fan × 1
Motor W 46 43
Air flow (at High) (Cooling)
CMM
20 38
Air filter, Q’ty Polypropylene net (washable) × 2
Shock & vibration absorber Cushion rubber (for compressor)
Electric heater ––
Operation control
Operation switch
Wireless-Remote control
Room temperature control Microcomputer thermostat
Pilot lamp RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Safety equipment
O.D mm (in) Liquid line: φ6.35 (1/4) Gas line: φ15.88 (5/8)
Connecting method Flare connecting
Attached length of piping Liquid line: 0.70m
Gas line: 0.63m
Insulation Necessary (Both sides)
Drain hose Connectable
Power source supply Terminal block (Screw fixing type)
Size × Core number 1.5 mm
2
× 4 cores (Including earth cable)
Connection wiring
Connecting method Terminal block (Screw fixing type)
Accessories (included)
Mounting kit, Clean filter (Natural enzyme filter × 1, Photocatalytic washable deodorizing filter × 1)
Optional parts Wired-Remote control
Notes (1) The data are measured at the following conditions.
2.2.2 SELECTION DATA
(1) Specifications
Model SRK19CES (Indoor unit)
SRC19CES (Outdoor unit)
Item Indoor air temperature Outdoor air temperature
Standards
Operation DB WB DB WB
Cooling 27ºC19ºC35ºC24ºC ISO-T1, JIS C9612
(2) The operation data are applied to the 220V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 15 m connecting piping.
(Purging is not required even in the short piping.)
If the piping length is longer, when it is 15 to 25m, add 20g refrigerant per meter.
Operation data
(1) (2)
Refrigerant
piping
Compressor: overheat protection, Frost protection, Serial signal error protection, Indoor fan motor error
protection
The piping length is 7.5m.
(220V)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi SRK19CES and is the answer not in the manual?

Mitsubishi SRK19CES Specifications

General IconGeneral
BrandMitsubishi
ModelSRK19CES
CategoryAir Conditioner
LanguageEnglish

Related product manuals