15
-
(8) Outline of cooling operation
(a) Operation of major functional components in cooling mode
Item
Indoor fan motor ON ON OFF
Flaps ON or OFF ON or OFF Stop position control
Display Lights up Lights up Lights up or flashes
52C ON ON OFF after stop mode
Outdoor fan motor OFF ON OFF
4-way valve
Depending on the stop mode
OFF
Depending on the stop mode
Electronic expansion valve Depending on the EEV control
Solenoid valve OFF OFF OFF
When the inverter
speed is 0rps
When the inverter speed
is other than 0rps
When the inverter speed is 0rps
due to an anomalous stop
Functional
components
(c) Detail of control in each mode (Pattern)
(i) Fuzzy operation
During the fuzzy operation, the air flow and the inverter speed are controlled by calculating the difference between the room
temperature setting correction temperature and the suction air temperature.
(ii) Cooling thermostat operation
1) Operating conditions
During the cooling fuzzy operation or when the speed obtained by the fuzzy calculation is less than -24 rps.
2) Detail of operation
(b) Air flow selection
(i) Speed of inverter changes within the range of selected air flow.
(ii) When any protective function actuates, the operation is performed in the mode corresponding to the function.
(iii) Outdoor blower is operated in accordance with the inverter command speed.
(iii) Cooling HI POWER operation (HI POWER button on remote control: ON)
The unit is operated continuously for 15 minutes regardless of the setting temperature.
1) Detail of operation
Model
SRK13ZEV-S
Item
Inverter speed 0 rps [Comp. stopped]
Indoor fan Corresponds to fan speed switch.
Outdoor fan Stop
Notes (1) Protective functions will actuate with priority even during the HI POWER operation.
(2) Room temperature is not adjusted during the HI POWER operation
Model
SRK13ZEV-S
Item
Inverter speed 94rps
Indoor fan 7th speed
Outdoor fan 6th speed
Model
SRK13ZEVS
Air flow selection
Inverter command speed 12~94rps
Air flow Depends on inverter command speed.
Inverter command speed 12~94rps
Air flow Depends on inverter command speed.
Inverter command speed 12~50rps
Air flow Depends on inverter command speed.
Inverter command speed 12~30rps
Air flow 2nd speed fixed.
Auto
HI
MED
LO

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi SRK19CES and is the answer not in the manual?

Mitsubishi SRK19CES Specifications

General IconGeneral
BrandMitsubishi
ModelSRK19CES
CategoryAir Conditioner
LanguageEnglish

Related product manuals