173
-
(12) Regulation of outdoor air flow
The fan operates as follows according to the outdoor air temperature.
S SRK19CES
Cooling, thermaldry
Outdoor air temp. (˚C)
32
2nd speed
1st speed
30
Functional
components
Compressor
EEV
control
Fully closed
OFF
OFF
Set location
ON
OFF
ON
ON
Outdoor unit fun
Indoor unit fun
Flap
EEV
Cooling,cooling oriented dehumidifying
Cooling,cooling oriented dehumidifying
Operation
Stop instructions All stop Stop instructions
Restart
When the complete stop command given, when
there is and abnormal stoppage command
When stoppage occurs due to thermostat operation,
switching operations and protective function operations
470 pulse
150 pulse
1 min.
1 min.
3 min.
2 min.55 sec.
2 min.55 sec.
470 pulse
(13) Stop mode
S SRK25CES
Cooling, thermaldry
Outdoor air temp. (˚C)
25
2nd speed
1st speed
23
3rd speed
3230