70
-
EXTERNAL INPUT
WIRED REMOCON
OPE PERMISSION
CUSTOM
AUTO RESTART
LO TEMP
DIRT PREVENT
COOL ONLY
HI CEIL
PANEL
50/60
(4) Custom cord switching procedure
If two wireless remote controls are installed in one room, in order to prevent wrong
operation due to mixed signals, please modify the printed circuit board in the indoor
units control box and the remote control using the following procedure. Be sure to
modify both boards. If only one board is modified, receiving (and operation) cannot
be done.
(a) Modifying the indoor units printed circuit board
Take out the printed circuit board from the control box and cut off jumper wire (J4)
using wire cutters.
After cutting of the jumper wire, take measures to prevent contact with the other the lead wires, etc.
(b) Modifying the wireless remote control
1) Remove the battery.
2) Cut the jumper wire shown in the figure at right.
(5) Flap and louver control
Control the flap and louver by AIRFLOW
(UP/DOWN) and
(LEFT/RIGHT) button on the wireless remote control.
(a) (i) Swing flap
Flap moves in upward and downward directions continuously.
(ii) Swing louver
Louver moves in left and right directions continuously.
(iii) When not operating
The flap returns to the position of air flow directly below, when operation has stopped.
(b) Multi-directional Air Flow (up/down air and left/right air scroll)
Activating both up/down air swing and left/right air swing at the same time results in a multi-directional air flow.
Up/down air scroll
Stops at this position
for 5 seconds.
In COOL, DRY and FAN operation
(c) Memory flap (Flap or Louver stopped)
When you press the AIRFLOW (UP/DOWN or LEFT/RIGHT) button once while the flap or louver is operating, it stops swinging
at an angle. Since this angle is memorized in the micro-computer, the flap or louver will automatically be set at this angle when the
next operation is started.
¡ Recommendable stopping angle of the flap
Horizontal
blowing
COOLDRY
Slant forward
blowing
HEAT
Left/right air scroll
In COOL, DRY and FAN operationIn HEAT operation
Stops at this position
for 5 seconds.
In HEAT operation
Left louver Right louver
Thick line : moves quickly
Thin line : moves slowly
Jumper wire (J4)
Cut

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi SRK25CES and is the answer not in the manual?

Mitsubishi SRK25CES Specifications

General IconGeneral
BrandMitsubishi
ModelSRK25CES
CategoryAir Conditioner
LanguageEnglish

Related product manuals