Level 1-2 Service Manual
12-December-2007 28
Troubleshooting
Manual Test Mode
Motorola W160/W156/W180/W175/W161/W181 telephones are equipped with a manual test
mode capability. This allows service personnel to verify functionality and perform fault
isolation by entering keypad commands.
To enter the manual test command mode, a GSM/DCS/PCS test SIM must be used.
1. Press and hold to turn the phone OFF.
2. Remove the battery as described in the procedures.
3. Remove the customerās SIM card from the phone as described in the procedures.
4. Insert the test SIM into the SIM slot.
5. Replace the battery as described in the procedures.
6. Press and hold to turn the phone ON.
Manual Test Mode Commands
Table 3: Manual Test Commands
Key Sequence Test Function/Name Remarks
#02# Handset information
#03#
RF information
#04#
ADC information
#09#
Simple Test mode
**0102#
FFS format
**0105#
Disable EFEM mode
*#06# IMEI number