10. Technical data
10.1 Technical data Temposonics
R-Series VRP5
Output
Interface PROFINET RT
PROFINET IRT version 2.3
Data protocol 0763URğOHDQG(QFRGHU3URğOH9
Data transmission rate 100 MBit/s (maximum)
Measured value Position, velocity/option: Simultaneous multi-position and multi-velocity measurements up to 30 magnets
Measurement parameters
Resolution: Position
0.5…100 μm (selectable)
Cycle time
Stroke length ≤ 50 mm ≤ 715 mm ≤ 2000 mm ≤ 4675 mm ≤ 6350 mm
Cycle time 250 µs 500 µs 1000 µs 2000 µs 4000 µs
Linearity deviation
4
Stroke length ≤ 500 mm > 500 mm
Linearity deviation ≤ ±50 µm < 0.01 % F.S.
Optional internal linearization/LQHDULW\WROHUDQFHDSSOLHVIRUWKHğUVWPDJQHWIRUPXOWLSRVLWLRQPHDVXUHPHQW
Stroke length 25…300 mm 300…600 mm 600…1200 mm 1200…3000 mm 3000…5000 mm 5000…6350 mm
typical ± 15 µm ± 20 µm ± 25 µm ± 45 µm ± 85 µm ± 95 µm
maximum ± 25 µm ± 30 µm ± 50 µm ± 90 µm ± 150 µm ± 190 µm
Repeatability < ±0.001 % F.S. (minimum ±2.5 m) typical
Hysteresis < 4 μm typical
Temperature coefficient < 15 ppm/K typical
Operating conditions
Operating temperature ũĽŹ&ũĽŹ)
Humidity 90 % relative humidity, no condensation
Ingress protection IP67 (connectors correctly fitted)
Shock test 150 g/11 ms, IEC standard 60068-2-27
Vibration test 30 g/10…2000 Hz, IEC standard 60068-2-6 (excluding resonant frequencies)
EMC test Electromagnetic emission according to EN 61000-6-3
Electromagnetic immunity according to EN 61000-6-2
The sensor meets the requirements of the EC directives and is marked with
Magnet movement velocity Magnet slider: Max. 10 m/s; U-magnet: Any; block magnet: Any
Design/Material
Sensor electronics housing Aluminum (painted), zinc die cast
Sensor profile Aluminum
Stroke length 25…6350 mm (1…250 in.)
Mechanical mounting
Mounting position Any
Mounting instruction
Please consult the technical drawings on page 9
Electrical connection
Connection type
2 × M12 female connectors (D-coded), 1 × M12 male connector (A-coded)
2 × M12 female connectors (D-coded), 1 × M8 male connector
Operating voltage +12…30 VDC ±20 % (9.6…36 VDC)
Power consumption Less than 4 W typical
Dielectric strength 500 VDC (DC ground to machine ground)
Polarity protection 8SWRũ9'&
Overvoltage protection Up to 36 VDC
4/ With position magnet # 252 182
Temposonics
®
R-Series V PROFINET IO RT & IRT
Operation Manual
I 37 I

Other manuals for MTS Sensors Temposonics R Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MTS Sensors Temposonics R Series and is the answer not in the manual?

MTS Sensors Temposonics R Series Specifications

General IconGeneral
BrandMTS Sensors
ModelTemposonics R Series
CategoryAccessories
LanguageEnglish

Related product manuals