13. Glossary
E
(QFRGHU3URğOH
7KHHQFRGHUSURğOHFRUUHVSRQGVWRWKHVSHFLğFDWLRQRIWKHHQFRGHU
SURğOH9312QR:LWKWKLVSURğOHWKHSRVLWLRQDQG
the velocity of one magnet can be measured and transferred
simultaneously. (J0763URğOH
Etrapoation
The native measurement cycle time of a sensor increases with the
stroke length. With extrapolation, the sensor is able to report data
faster than the native cycle time, independent of the stroke length of
the sensor. Without extrapolation, if data is requested faster than the
native cycle time, the last measured value is repeated.
)
),5)LOWHU
7KH),5ğOWHU)inite ,mpulse esponse) is used to smooth the
measured position value before output. To determine the output
YDOXHRQO\LQSXWYDOXHVFRUUHVSRQGLQJWRWKHZLQGRZğOWHUZLQGRZ
VL]HDUHXVHGIRUğOWHUFDOFXODWLRQ7KHRXWSXWYDOXHLVFDOFXODWHG
from these input values in the form of a moving average value.
(Jb,,5)LOWHU
S
7KHSURSHUWLHVDQGIXQFWLRQVRID352),1(7,2ğHOGGHYLFHDUH
GHVFULEHGLQD*6'0/ğOHeneral Station escription). The XML-
EDVHG*6'0/ğOHFRQWDLQVDOOUHOHYDQWGDWDWKDWDUHLPSRUWDQWIRU
the implementation of the device in the controller as well as for
GDWDH[FKDQJHGXULQJRSHUDWLRQ7KH*6'0/ğOHRIWKH56HULHVV
PROFINET is available on the homepage
www.mtssensors.com.
,
,,5)LOWHU
7KH,,5ğOWHU,QLWH,mpulse esponse) is used to smooth the
measured position value before output. To determine the outputvalue,
WKHLQSXWYDOXHVFRUUHVSRQGLQJWRWKHğOWHUJUDGHğOWHUZLQGRZVL]H
DUHXVHGIRUWKHğOWHUFDOFXODWLRQ7KHSUHYLRXVYDOXHVDUHDOVRWDNHQ
into account when calculating the output value. (J FIR Filter)
,QWHUQDO/LQHDUL]DWLRQ
The internal linearization offers an improved linearity for an
overall higher accuracy of the position measurement. The internal
linearization is set for the sensor during production.
,57
With PROFINET IRT (,sochronous eal ime) a clock-synchronous
data transmission takes place. The application, the data transmission
as well as the device cycle are synchronous. IRT enables a clock-
V\QFKURQRXVGDWDH[FKDQJHZLWKDPLQLPXPF\FOHWLPHRIŷVLQ
the network. The R-Series V PROFINET supports PROFINET RT and
IRT. (J RT)
asrin irtion
When moving the position magnet, the position and velocity values
increase in the measuring direction.
Forward: Values increasing from sensor electronics housing
WRURGHQGSURğOHHQG
5HYHUVH9DOXHVLQFUHDVLQJIURPURGHQGSURğOHHQGWRVHQVRU
electronics housing
0763URğOH
7KH076SURğOHZDVGHYHORSHGE\0766HQVRUVDQGLVWDLORUHGWR
the characteristics of magnetostrictive position sensors. With this
SURğOHWKHSRVLWLRQVDQGYHORFLWLHVRIXSWRPDJQHWVFDQEH
reported and transferred simultaneously. (J(QFRGHU3URğOH
tiposition asrnt
During the measurement cycle, the positions of every magnet on
the sensor are simultaneously reported. The velocity is continuously
calculated based on these changing position values as the magnets
are moved.
st
A value which will be added or deducted to the actual position value.
This leads to a shift of the measurement range start. (Jb3UHVHW

A PLC (rogrammable ogic ontroller) is a device for controlling or
regulating machines and systems.
rst
With the preset, a value is entered for the current position which is
to be output at this position in the future. The difference between the
entered value and the currently easured position is calculated as an
offset. (J Offset)
352),1(7
PROFINET (rocess )Leld twork) is an Industrial Ethernet interface
and is managed by the ROFIBUS utzerorganiation e.V. (PNO).
The R-Series V352),1(7DQGLWVFRUUHVSRQGLQJ*6'0/ğOHDUH
FHUWLWLğHGE\WKH312

RO (ead nly) means that the value of the variable can only be read
EXWLVQRWPRGLğDEOH

With PROFINET RT (eal ime) the data exchange is without clock
synchronization. In this case, the application, the data transmission
DQGWKHğHOGGHYLFHVRSHUDWHDFFRUGLQJWRWKHLURZQSURFHVVLQJ
cycle. The R-Series V PROFINET supports PROFINET RT and IRT.
(J IRT)

RW (ead/ rite) means that the value of the variable can be read
DQGZULWWHQ7KHYDOXHRIWKHYDULDEOHLVPRGLğDEOH
Temposonics
®
R-Series V Profinet RT & IRT
Operation Manual

Other manuals for MTS Sensors Temposonics R Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MTS Sensors Temposonics R Series and is the answer not in the manual?

MTS Sensors Temposonics R Series Specifications

General IconGeneral
BrandMTS Sensors
ModelTemposonics R Series
CategoryAccessories
LanguageEnglish

Related product manuals