Installation Section 2
2-16
Part Number 020002777 10/11
Model 138EDA2
1. Locate the Barb-stem splicers and tab-clamps in the
installation kit.
NOTE: The Installation Kit provides syrup connections
for 1/2 or 3/8 ID conduits. The circulating carbonated
Water Lines are supplied with 1/2 Barbs only. Determine
the conduit size prior to the attaching Barb systems.
2. Attach the 1/4" Barb of the 1/4" x 1/2" or 1/4" x 3/8"
Barb splicer to the Syrup Lines in the tower labeled
#1, #2, #4, #5, #6, #7, and #8. clamp in place with
tab clamp.
3. Attach the four (4) 1/2" x 1/2" Barb splicers to the
tower lines labeled "AF or AR" and "BF or BR".
Clamp in place with tab clamp (refer to "Note"
below).
4. Route the beverage conduit up to the tower. If the
lines of the conduit are different lengths, always
connect the shortest line first. Use two (2) tab
clamps per connection.
5. Using the plumbing diagram (located in this manual)
as a guide for steps 5 through 7 attach the tower
Syrup Lines labeled #1, #2, #3, #4, #5, #6, #7 and
#8 to the corresponding numbered or colored line of
the conduit. Clamp in place.
6. Connect the plain water supply to the line labeled
"WF or WR". clamp with tab clamp.
7. Attach the Carbonated Water Line to the line labeled
"AF or AR" and "BF or BR". Clamp in place.
NOTE: If a Single Circuit is used, run "AF or AR" In and
"AF or AR" Out to "BF or BR" In. Route "BF or BR" back
to conduit.
Model 115, & 116
1. Locate the Barb-stem splicers and tab-clamps in the
installation kit.
NOTE: The Installation Kit provides syrup connections
for 1/2 or 3/8 ID conduits. The circulating carbonated
Water Lines are supplied with 1/2 Barbs only. Determine
the conduit size prior to the attaching Barb systems.
2. Attach Barb splicer to the syrup lines labeled #1, #2,
#3, #4, and #5 ("6" and "W" if it is a six (6) valve
tower). Clamp in place with ta clamps. Attach the
two (2) 1/2 x 1/2 Barb splicers to the lines labeled #7
Carbonated Water and #8 Carbonated Water then
clamp in place.
3. Attach the syrup lines labeled #1, #2, #3, #4, #5, and
#6 (for six (6) valve towers application only) to the
corresponding numbered or colored lines of the
conduit. Clamp in place using two (2) clamps each.
4. Connect the plain water line (labeled "W") to the
plain water supply and clamp in place (for six (6)
valve tower application only).
5. Attach the Carbonated Water line to the line labeled
#7 Carbonated Water and #8 Carbonated Water,
then clamp in place.