Section 2 Installation
Part Number 020002777 10/11 2-17
Model 156, 158, & 1510
1. Route the Beverage Conduit up to the stainless
steel Barb Stem Adaptors at the base of the tower. If
the lines of the conduit are of different lengths,
always connect the shortest line first. Use two (2)
tab clamps at every connection.
NOTE: The Model 158 and 1510 Pass-Thru towers have
two (2) internal Carbonated Water Circuits. Use the
Carbonated Water lines #8, and #9 to connect to the
lines labeled "xF or xR" and "A". Connect the
Carbonated Water Lines labeled #7 and #10 to the lines
labeled "xF or xR" and "B". If the refrigeration unit has
only one (1) Carbonated Water Circuit, these lines must
be connected together.
2. Attach the syrup lines labeled "1" through "6", "1"
through "8", or "1" through "10" to the corresponding
numbered Barb fittings of the tower. Use two (2) tab
clamps per connection.
3. Attach the Non-carbonated Water Line (labeled "W")
of the beverage conduit to the Barb Stem of the
tower labeled "W". Use two (2) tab clamps.
Model 126LDP
1. Route the beverage conduit up to the base of the
tower. If the lines of the conduit are different lengths,
always connect the shortest line first. Use two (2)
Tab Clamps at every connection.
NOTE: The Multiplex Model 126 Front Draw Dispensing
Tower has only one internal carbonated water circuit.
2. Attach the six (6) Syrup Lines labeled 1, 2, 3, 4, 5,
and 6 to the corresponding numbered Barb Fittings
of the tower. Use two (2) tab clamps per connection.
If conduit has non-numbered colored tubing, use the
"Conduit Number to Color Reference Chart" listed in
these instructions.
3. Attach the Plain Water line (labeled "W") of the
beverage conduit to the Barb System of the tower
labeled "W". Use two (2) tab clamps. If six (6)
Carbonated Water Valves are required, use 1/4" tee
provided to connect the carbonated line to "W" line.