Chapter 11 Triggering
M Series User Manual 11-6 ni.com
Figure 11-6. Analog Edge Triggering with Hysteresis Falling Slope Example
Analog Window Triggering
An analog window trigger occurs when an analog signal either passes into
(enters) or passes out of (leaves) a window defined by two voltage levels.
Specify the levels by setting the window Top value and the window Bottom
value.
Figure 11-7 demonstrates a trigger that asserts when the signal enters the
window.
Figure 11-7. Analog Window Triggering Mode (Entering Window)
Analog Comparison Event
Hysteresis
High threshold
(Level + Hysteresis)
Low threshold
(Level)
First signal must go
above high threshold
Then signal must go below low threshold
before Analog Comparison Event asserts
To p
Analog Comparison Event
Bottom

Table of Contents