Technical specifications
AG-AC10-65
3x400V1x230V
Output data
1,570/7,650WCooling capacity 35°C
1)
/ 27°C
2)
, min/max
1,820/8,670WHeat capacity 7 °C
1)
/ 20 °C
2)
, min/max
5,920WHeat capacity -7°C
1)
/ 20 °C
2)
, max
4,260WHeat capacity -22°C
1)
/ 20 °C
2)
, max
6,500 W/6.49/A++Pdesignc/SEER/Energy class (cooling +35 °C)
3)
6,400 W/4.1/A+Pdesignh/SCOP/Energy class (heat -10 °C)
3)
Electrical data
400V 3N~50 Hz230V~50 HzRated voltage
5,200/10x32,600/12W/AMax. specified power/operating current
16AFuse
Refrigerant circuit
R410AType of refrigerant
Twin rotaryType of compressor
2.7kgVolume
Pipe connections
6.35 (1/4")mm
(inches)
Pipe connection (liquid)
12.77(1/2")*9.52 (3/8")*mm
(inches)
Pipe connection (gas)
0.8mmMin. thickness refrigerant pipe
Recommended working range
4)
-20/50°CMin/max outdoor temp. during cooling
10/32°CMin/max indoor temp. during cooling
-32/24°CMin/max outdoor temp. during heating
0/27°CMin/max indoor temp. during heating
Miscellaneous
64kgWeight
1,030mmWidth
400mmDepth
735mmHeight
47dB(A)Max. sound pressure level at 2 m, according to ISO 9614
IPX4Enclosure class
064 167064 168Part No.
1)
Refers to the outdoor temperature.
2)
Refers to the indoor temperature.
3)
According to EN 14825.
4)
The performance test is carried out within the specified temperature range, where operation outside the working range is possible with
maintained function.
*)
Transition nipples are included to fit the indoor units.
27Chapter 9 | Technical dataAG-AC10