Safety precautions
NOTE
Avoid the use and storage of flammable li-
quids near the climate unit.
Never install electric equipment that does not
have IPX1 protection (protection against ver-
tical water drops), under the unit.
The manufacturer assumes no liability, if safety the
standards or protection preventive measures are not
complied with.
Special safety measures
During installation the cooling circuit must be connected
first and then the electrical circuit. Perform in reverse
order when removing the unit.
During repair
Disconnect the voltage (via the main switch) before
opening the unit to check or repair the electrical parts.
Keep hands and clothing away from moving parts.
Clean after completing the work, and check that no
metal residue or cable parts have been left inside the
unit.
Vent the premises during the installation and the
cooling circuit test. Ensure that no refrigerant gas has
leaked out during the installation, as contact with na-
ked flames or heat sources can be toxic or dangerous.
Read before starting the
installation
This heat pump complies with strict safety and function
standards.
It is very important that the installer or the service tech-
nicians install or repair the system so that it works safely
and efficiently.
For a safe installation and good function the
following is required:
Read this instruction manual carefully before starting
installation.
Follow the installation and safety instructions exactly
as described and shown.
Comply with local and national electrical regulations.
Note all the warning and safety messages indicated
in this manual.
The unit must be connected to a separate supply.
These instructions are sufficient for installation and
maintenance. If assistance is required for a particular
problem, contact our dealer for further information.
NIBE does not accept any responsibility for damage that
occurs in the event of incorrect installation or improper
maintenance.
Electrical requirements
NOTE
The electrical discharge can cause serious per-
sonal injury or death. Only qualified electricians
may handle the electrical system.
Before installation ensure that the mains supply for
the power supply is the same as that indicated on the
climate unit's rating plate.
Each unit must be connected with approved grounded
cable.
The electrical connections must be performed by a
specially trained and qualified electrician.
Ensure a ground connection before the unit is
powered.
Hazardous electrical voltage is used in this electrical
circuit. See electrical wiring diagram and its instructions
below the connection. Incorrect connections or unsuit-
able ground connection can cause accidents or death.
The yellow/green cable must not be used for connec-
tions other than ground.
Tighten the cables securely. Incorrect connections can
cause overheating and fire.
Electrical cables must not come into contact with the
cooling pipes, the compressor or fan's moving parts.
Use separate cables for each type of cable.
5Chapter 1 | Important informationAG-AC10

Questions and Answers:

Nibe AG-AC10-65 Specifications

General IconGeneral
BrandNibe
ModelAG-AC10-65
CategoryHeat Pump
LanguageEnglish

Summary

Important Information

Safety Information and Symbols

Key safety information and explanations of symbols used in the manual.

Product Identification and Compliance

Information on identifying the product and its compliance markings.

Environmental and Disposal Guidelines

Guidance on proper product recycling, disposal, and environmental impact.

Safety Precautions and Installation Readiness

Detailed safety measures, pre-installation checks, and electrical requirements for safe installation.

Delivery and Handling

Transport and Assembly Recommendations

Procedures and recommendations for safely transporting and assembling the unit.

Installation Site Selection and Area

Guidance on selecting an appropriate installation location and required clearance.

Supplied Components List

List of components included with the outdoor unit package.

Pipe Connections

General Pipe Installation and Condensation Drain

General guidelines for pipe installation and condensation drainage according to norms.

Cooling Circuit Connection Details

Instructions and diagrams for connecting the cooling circuit pipes to indoor units.

Electrical Connections

General Electrical Safety and Power Connection

Crucial safety guidelines and requirements for electrical connections and power supply.

230V Outdoor Unit Wiring

Wiring diagram for connecting the outdoor unit to one indoor unit at 230V.

400V Outdoor Unit Wiring

Wiring diagrams for connecting the outdoor unit to indoor units at 400V.

Connecting Optional Accessories

Instructions for connecting optional accessories, such as the condensation water pipe.

Installation

General Installation and Model Combinations

Overview of model combinations and step-by-step physical installation of the outdoor unit.

Pump Down Procedure

Procedure for retrieving refrigerant before moving or repairing the cooling circuit.

Indoor Unit Addressing and Configuration

Setting cooling circuit addresses for indoor units to communicate with the outdoor unit.

The Main Functions of the Valves

Valve Operation and Service

Description of how to operate and use the 2-way and 3-way service valves.

Disturbances in Comfort

Troubleshooting Common Issues

Guidance on diagnosing and resolving common operational issues and disturbances.

Fault Code Interpretation

Explanation of fault codes indicated by LEDs for troubleshooting.

Accessories

Condensation Water Management

Details on condensation water pipes for routing water to an external drain.

Hot Water Module and Mounting Options

Information on the hot water module and options for mounting the unit.

Technical Data

Unit Dimensions

Physical dimensions of the outdoor unit presented in millimeters.

Technical Specifications and Performance

Detailed technical specifications including electrical, refrigerant, and operating parameters.

Electrical Circuit Diagrams

Schematic diagrams illustrating the electrical wiring of the unit.

Item Register

Alphabetical Index of Topics

An alphabetical index of topics covered in the manual for quick reference.

Related product manuals