LIFT FROM THE STREET TO THE SET UP
LOCATION
If the base allows, the simplest thing is to use a pallet
truck to move the F2120 to the set up location.
NOTE
The centre of gravity is offset to one side (see
print on the packaging).
If F2120 needs to be transported across soft ground,
such as a lawn, we recommend that a crane is used
that can lift the unit to the installation location. When
F2120 is lifted with a crane, the packaging must be un-
disturbed, see the illustration above.
If a crane vehicle cannot be used the F2120 can be
transported on an extended sack truck. F2120 must be
taken from its heaviest side and two people are required
to lift F2120.
LIFT FROM THE PALLET TO FINAL
POSITIONING
Before lifting remove the packaging and the securing
strap to the pallet.
Place lifting straps around each machine foot. Lifting
from the pallet to the base requires four persons, one
for each lifting strap.
SCRAPPING
When scrapping, the product is removed in reverse or-
der. Lift by the bottom panel instead of a pallet!
Compressor heater
F2120 is equipped with two compressor heaters that
heat the compressor before start-up and when the
compressor is cold.
NOTE
The compressor heater must have been active
for approx. 3 hours before the first start, see
section “Start-up and inspection” on page 34.
Condensation
The condensation water trough collects and leads away
most of the condensation water from the heat pump.
NOTE
It is important to the heat pump function that
condensation water is led away and that the
drain for the condensation water run off is not
positioned so that it can cause damage to the
house.
Condensation runoff should be checked regu-
larly, especially during the autumn. Clean if
necessary.
NOTE
The electrical installation and wiring must be
carried out under the supervision of an author-
ised electrician.
TIP
Pipe with heating cable for draining the con-
densation water trough is not included.
To ensure this function the accessory KVR 10
should be used.
• The condensation water (up to 50 litres/24 hrs) that
collects in the trough should be routed away by a pipe
to an appropriate drain, it is recommended that the
shortest outdoor stretch possible is used.
• The section of the pipe that can be affected by frost
must be heated by the heating cable to prevent
freezing.
• Route the pipe downward from F2120.
• The outlet of the condensation water pipe must be at
a depth that is frost free or alternatively indoors (with
reservation for local ordinances and regulations).
NIBE F2120Chapter 2 | Delivery and handling10