The FIGHTER 1210 consists of a heat pump, water
heater, electrical element, circulation pumps, a soft-
start relay and control computer with display. FIGHT-
ER 1210 is connected to the collector and heating
medium circuits.
The heat from the heat source (rock,
soil, lake)
is taken
up via a closed collector system in which a mixture of
water and antifreeze circulates. Groundwater can also
be used as a heat source, but this requires an inter-
vening heat exchanger.
The brine emits its heat to the refrigerant in the heat
pump’s evaporator. It then vaporises and is com-
pressed in the compressor. The refrigerant, the tem-
perature of which has now been raised, is passed to
the condenser where it gives off its energy to the heat-
ing medium circuit and, if necessary, to the water
heater. After the condenser there is a built-in electrical
module which cuts in if there is a high demand.
System description
3
For Home Owners
FIGHTER 1210
Principle of operation
The heating medium side and
the hot water side must be fit-
ted with the necessary safety
equipment in accordance with
the applicable regulations.
Hot water
circulation
Heating water
pump
Immersion heater
3 way valve
Heating water
flow
Heating water
return
Evaporator
Brine pump
Compressor
Condenser
Expansion valve
Cooling unit
Double jacket
Brine in
Brine out
Water heater