10 – ENGLISH
4.2 WIRING DIAGRAM AND DESCRIPTION OF CONNECTIONS
4.2.1 Wiring diagram
FLASH
STOP
AERIAL
NO
NC
8K2
OSE
TX
1 2
RX
1 2
OPEN
NO
FUSE
KEYS
LED
FUSE
RECEIVER
Flash Alarm
Bluebus
StopSbSOpenLight
Light
BUZZER
DOOR
CONTROL
14
4.2.2 Description of connections
Table 5
ELECTRICAL CONNECTIONS
Terminals Description
ALARM This (programmable) output is congured as default for alarm system notications.
FLASH
This output is programmable (refer to the “PROGRAMMING” chapter) to connect one of the following devices:
Warning light, “Door open indicator” output, Suction cup [note 1], Electric latch [note 1], Electric lock
[note 1].
If programmed as “warning light”, on the “FLASH” output it is possible to connect a “LUCYB” warning light
or similar with a single 12 V maximum 21 W car-type lamp. During the manoeuvre, check that the warning light
ashes at intervals of 0.5 seconds on and 0.5 seconds off.
If programmed as “door open indicator”, on the “FLASH” output it is possible to connect a 24 V max 5 W
indicator light to signal the door open status. It can also be programmed for other functions (refer to the “PRO
GRAMMING” chapter).
If programmed as “suction cup”, on the “FLASH” output it is possible to connect a 24 V max 10 W suction
cup (versions with electromagnet only, without electronic devices). When the door is closed, the suction cup is
activated to lock the door in place. During the opening and closing manoeuvre, it is deactivated.
If programmed as “electric latch”, on the “FLASH” it is possible to connect a 24 V max 10 W electric device
with latch (versions with electromagnet only, without electronic devices).
During the opening manoeuvre, the electric latch is activated and remains active to free the door and perform
the manoeuvre.
During the closing manoeuvre, ensure that the electric latch re-engages mechanically.
If programmed as “electric lock”, on the “FLASH” output it is possible to connect a 24 V max 10 W electric
lock with latch (versions with electromagnet only, without electronic devices).
During the opening manoeuvre, the electric lock is activated for a brief interval to free the door and perform the
manoeuvre. During the closing manoeuvre, ensure that the electric lock re-engages mechanically.
Note 1 Only devices containing the electromagnet only can be connected.

Table of Contents

Other manuals for Nice SO2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nice SO2000 and is the answer not in the manual?

Nice SO2000 Specifications

General IconGeneral
BrandNice
ModelSO2000
CategoryGarage Door Opener
LanguageEnglish

Related product manuals