AF accuracy inspection and adjustment (Make all the
following adjustments.)
②
YAW, PITCH inspection and adjustment
③
LARK adjustment (inc.
CCD output adjustment)
〔Tools required〕
1. When adjusting for all adjustment items
ref. Page A35.
2. When inspecting AF accuracy
① AF
adjustment lens (J18266)
②
AF adjusting tool (J15259
)
③
Lens holder for F4 (J15280)
④
AF chart
(J18344)
⑤
Chart illuminator for AF
(J15264)
3. When adjusting YAW, PITCH
YAW, PITCH tool
(
J18230
)
4. When adjusting LARK
The above tool when inspecting AF accuracy
Note:
When using the adjustment software for the rst time, prepare 5 camera of D70 and input the average
value of the 5 cameras, which was measured when checking the AF accuracy, in "WRITING OF AF ADJ.
LENS OFFSET VALUE" on the main menu.
①
AE CCD alignment inspection and adjustment
(
ref. Page A26 for details
)
②
AE accuracy inspection and adjustment
③
Aperture accuracy inspection
④
Adjustment for battery check level (Use the battery tool (J61197) and stabilized power supply.
)
⑤
Built-in SB ash inspection and adjustment
〔Tools required〕ref. Page A35.
・
Inspection on Battery check indications
After the battery check adjustment, input each voltage of the below into camera, and check the indications of the
outer LCD.
Note: Make an inspection by switching the voltage in the order of
①
-
⑦
.
AE inspection and adjustment
Outer LCD indication
Set voltage of Stabilized power supply
①
9.00V
⑦
8.23V±0.1V
②
7.98V±0.1V
⑥
8.15V±0.1V
③
7.85V±0.1V
⑤
8.05V±0.1V
④
7.80V±0.1V
Blink
・
Built-in SB ash inspection and adjustment
Set the distance between camera and ash meter to 1 m, and inspect and adjust the light volume of the built-
in SB. (ref. adjustment software for details)
*
Note: After the adjustment ends, arrange the
connection FPC inside the cover.
Connection FPC