VBA10401-R.3623.A
- A50 ・ -
7. Required equipment and conditions
※ AC adapter EH-5 and USB cable (mini B type) UC-E4 are used for all adjustments so they are not
specied in the list.
Item Required equipment Setting/Remarks
1 Sensitivity adjustment
・5100K color viewer J63070
(ex-model viewer J63049 is also
available.)
・Luminance meter BM-3000
J63068
・Tool lens(to x aperture) J61185
・ND lter
(ND8×1+ND4×2)
Equivalent to luminance LV13
Aperture F8
52 mm,7-step light reduction; Use
the packaged product
2 Gr/Gb compensation
adjustment (R/B lter)
・5100K color viewer J63070
(ex-model viewer J63049 is also
available.)
・Luminance meter BM-3000
J63068
・Tool lens(Fixed aperture) J61185
・SP3 (R lter) J63087
・SP1 (B lter) J63085
Equivalent to luminance LV13
Aperture F8
3 Sensitivity ratio adjustment
・5100K color viewer J63070
(ex-model viewer J63049 is also
available.)
・Luminance meter BM-3000
J63068
・Tool lens(to x aperture) J61185
Equivalent to luminance LV13
Aperture F8; No lter
4 CCD black point defect
compensation
・5100K color viewer J63070
(ex-model viewer J63049 is also
available.)
・Luminance meter BM-3000
J63068
・Tool lens(to x aperture) J61185
Equivalent to luminance LV13
Aperture F5.6
5 CCD white point defect
compensation
Body cap or lens cap Environmental temperature approx.
20 - 25℃
6 Sensitivity, sensitivity ratio
reference value calculation
Same as "Sensitivity adjustment" No lter when sensitivity ratio
reference value is calculated.
7 TFT view angle adjustment None Only for NTSC (unnecessary for
PAL)
8 CCD PCB EEPROM ashram
up
None
9 TFT PCB EEPROM ashram
up
None
10 Reading of RISC version None