Before starting
Please check that the following documents have been supplied with the unit:
- Installation instructions (this manual)
- Operating instructions for CTS 602 controls
- Wiring diagram
Should you have any questions on how to operate the system, contact your nearest Nilan dealer,
who you can find at
www.nilan.dk/dealers
Compact S is a heat recovery ventilation system with a capacity of up to 330m
3
/h at 100Pa exter-
nal counter pressure. The energy of the exhaust air is transferred via a heat pump to a 180litres
hot water tank as first priority and to the inlet air as second priority.
The system can be equipped with G4 duct filter. Other optional extras are also available, including
hygrostat and pollen filter unit.
The system is operated via CTS 602 controls offering a wide range of functions, including menu-
based operation, weekly programming, timed filter alarm, fan speed adjustment, etc. The CTS 602
controls are described in a separate manual supplied together with the system.
For details of spare parts and accessories under Figure 25 “accessories”
Compact S is supplied in a white Aluzink cabinet, fully tested and ready to operate. Installation and
start-up must only be performed by a qualified electrician.
Note: The water tank must be filled with water before the unit start up.