NSI DS8/DS12 MODULAR DIGITAL DIMMING SYSTEM
Software Revision 1.1x, 8/24/99
- 6 -
___________________________________________________________________
DS Pack Operation
The Operation of the DS Pack has been divided into the following sections:
1. Turn Lights On…Now!
2. Setup
3. Softpatch
4. Analog Submasters
5. Presets
6. Dimmer Feedback
7. Control Module Jumper Settings
8. Contact NSI
__________________
Section 1 1. Make sure all three red led power indicators on the front are lit.
2. Make sure lighting loads are plugged into back of pack .
To turn lights on now: 3. Flip all circuit breakers up to "ON" position.
4. Press test switch oval under each circuit breaker.
1.1 Setting the Test Switch Bump or Latch action and level:
If the test switches have been configured as " latch" action, the lights will stay on at the first press of the test switch,
but if the test switches have been configured as "bump" action, they will only stay on as long as they are pressed.
To change the test switch action, and the test switch intensity, press [CLEAR] until the following menu is displayed:
NSI DSxx xPHASE Note: the 'x's could indicate a variety of settings
STATUS=xxx [MORE]
Now press the switch under [MORE] twice. This switch is a soft switch, that is, the function of the switch is defined
by the bracketed text in the LCD window above. If you are lost or make a mis-entry, just hit [CLEAR]. The menu
will back up one position or one menu each time [CLEAR] is pressed. The LCD should now display:
NSI DSxx xPHASE
[SETUP] [MORE]
Press the soft switch under [SETUP]. Then press [MORE] 2 times. The screen should now display :
SET TEST SWITCH
[ACTION] [MORE]
Select [ACTION]. Two choices will be displayed [LATCH] and [BUMP]. Press the test function you prefer.
This selection will stay in permanent EEPROM memory. Upon selection, another choice will appear:
SET TEST LEVEL = 25%
[CHANGE] [MORE]
If you wish to change the output intensity of the bump switches, select [CHANGE]. This change is in volatile
memory, or RAM , so it will go back to 25% when the power to the pack turned off. The level setting will not take
effect, however, until the test switch is activated again.