2.5 Factory Defaults Selection:
There are an abundance of functions that are initialized if this selection is made:
• All non-analog presets in memory ( Presets 13 through 400 ) are completely erased.
• Both DMX-512 and Microplex softpatches default to 1:1 at full on channels 1 through 12.
• Luma-Net patch defaults to dimmer 1.
• The dimmer pack is set to 12 channel, 3 phase operation.
• All dimmer curves default to dim operation.
• All dimmer maximum levels are set to Full.
• All dimmer minimum levels are set to O.
• Line regulation is set to "ON"
If you wish to continue, from the main menu:
NSI DSxx xPHASE
STATUS=xxx [MORE]
Press the key sequence [MORE], [MORE], [SETUP], [MORE], [MORE], [MORE], [MORE], [MORE]. The
following menu will be displayed:
SET FACTORY
[DEFAULTS] [MORE]
If you wish to completely clear all memory other than the analog input patch, press [DEFAULTS]. The following
menu will appear:
ARE YOU SURE? IF
SO PRESS [ENTER]
If you are not sure, press any key except [ENTER] to return to the previous menu. If you are sure, press [ENTER],
and a message of " WRITING DATA …" will be displayed for several seconds while all permanent memory is re-
programmed.
2.6 Luma-Net Start Address
This menu sets the start address for dimmer 1 for Luma-net operation of the dimmer pack. Note that it is not
necessary to softpatch any other functions for Luma-Net operation, because the softpatch and levels are stored in the
Luma-Net stations themselves. If you wish to change the Luma-Net start address, then from the main menu:
NSI DSxx xPHASE
STATUS=xxx [MORE]
press the key sequence [MORE], [MORE], [SETUP], [MORE], [MORE], [MORE], [MORE], [MORE],
[MORE]. The following menu will be displayed:
SET LUMA-NET= 001
[CHANGE] [MORE]
If you wish to change the Luma-Net start address, press [CHANGE], and then enter the start address you desire. The
new address will be stored in permanent EEPROM memory, and will automatically load on power-up.