NSI DS8/DS12 MODULAR DIGITAL DIMMING SYSTEM
Software Revision 1.1x, 8/24/99
- 9 -
2.5 Factory Defaults Selection:
There are an abundance of functions that are initialized if this selection is made:
All non-analog presets in memory ( Presets 13 through 400 ) are completely erased.
Both DMX-512 and Microplex softpatches default to 1:1 at full on channels 1 through 12.
Luma-Net patch defaults to dimmer 1.
The dimmer pack is set to 12 channel, 3 phase operation.
All dimmer curves default to dim operation.
All dimmer maximum levels are set to Full.
All dimmer minimum levels are set to O.
Line regulation is set to "ON"
If you wish to continue, from the main menu:
NSI DSxx xPHASE
STATUS=xxx [MORE]
Press the key sequence [MORE], [MORE], [SETUP], [MORE], [MORE], [MORE], [MORE], [MORE]. The
following menu will be displayed:
SET FACTORY
[DEFAULTS] [MORE]
If you wish to completely clear all memory other than the analog input patch, press [DEFAULTS]. The following
menu will appear:
ARE YOU SURE? IF
SO PRESS [ENTER]
If you are not sure, press any key except [ENTER] to return to the previous menu. If you are sure, press [ENTER],
and a message of " WRITING DATA …" will be displayed for several seconds while all permanent memory is re-
programmed.
2.6 Luma-Net Start Address
This menu sets the start address for dimmer 1 for Luma-net operation of the dimmer pack. Note that it is not
necessary to softpatch any other functions for Luma-Net operation, because the softpatch and levels are stored in the
Luma-Net stations themselves. If you wish to change the Luma-Net start address, then from the main menu:
NSI DSxx xPHASE
STATUS=xxx [MORE]
press the key sequence [MORE], [MORE], [SETUP], [MORE], [MORE], [MORE], [MORE], [MORE],
[MORE]. The following menu will be displayed:
SET LUMA-NET= 001
[CHANGE] [MORE]
If you wish to change the Luma-Net start address, press [CHANGE], and then enter the start address you desire. The
new address will be stored in permanent EEPROM memory, and will automatically load on power-up.