9 Servo Parameter Objects
9 - 30
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
9-5 Interface Monitor Settings
• Set the function and logic for general-purpose input 1 (IN1).
Refer to 3-1-7 Control Input Details on page 3-9, as well as 7-1-1 Input Signals on page 7-2.
• Set the function and logic for general-purpose input 2 (IN2).
Refer to 3-1-7 Control Input Details on page 3-9, as well as 7-1-1 Input Signals on page 7-2.
• Set the function and logic for general-purpose input 3 (IN3).
Refer to 3-1-7 Control Input Details on page 3-9, as well as 7-1-1 Input Signals on page 7-2.
• Set the function and logic for general-purpose input 4 (IN4).
Refer to 3-1-7 Control Input Details on page 3-9, as well as 7-1-1 Input Signals on page 7-2.
• Set the function and logic for general-purpose input 5 (IN5).
Refer to 3-1-7 Control Input Details on page 3-9, as well as 7-1-1 Input Signals on page 7-2.
3400 hex
Input Signal Selection 1
Setting
range
0 to 00FF FFFF hex
Unit
–
Default
setting
0094 9494 hex Data
attribute
C
Size 4 bytes (INT32) Access RW PDO map Not possible
3401 hex
Input Signal Selection 2
Setting
range
0 to 00FF FFFF hex
Unit
–
Default
setting
0081 8181 hex Data
attribute
C
Size 4 bytes (INT32) Access RW PDO map Not possible
3402 hex
Input Signal Selection 3
Setting
range
0 to 00FF FFFF hex
Unit
–
Default
setting
0082 8282 hex Data
attribute
C
Size 4 bytes (INT32) Access RW PDO map Not possible
3403 hex
Input Signal Selection 4
Setting
range
0 to 00FF FFFF hex
Unit
–
Default
setting
0022 2222 hex Data
attribute
C
Size 4 bytes (INT32) Access RW PDO map Not possible
3404 hex
Input Signal Selection 5
Setting
range
0 to 00FF FFFF hex
Unit
–
Default
setting
002B 2B2B hex Data
attribute
C
Size 4 bytes (INT32) Access RW PDO map Not possible
All
All
All
All
All

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron R88D-KN02H-ECT-L and is the answer not in the manual?

Omron R88D-KN02H-ECT-L Specifications

General IconGeneral
BrandOmron
ModelR88D-KN02H-ECT-L
CategoryServo Drives
LanguageEnglish

Related product manuals