18
9
Monitoring communication data
9.1.2 Input/output list display
Step1
At the initial screen, select
[MONITOR]
[I/O].
The "DI Monitor 1" screen then displays.
"SI MONITOR 1" screen
Step2
Select the input/output monitor to
be displayed.
Pressing the F2 key (DI)--F10 key (SOW)
displays the input/output monitor
corresponding to the key.
Pressing the MONITOR key changes the port
number.
Key Input/output
F2 DI
F3 DO
F4 MO
F5 LO
F6 TO
F7 SI
F8 SO
F9 SIW
F10 SOW
Press the [ESC] key to end the monitor
display.
9.1.3 Input/output details display
Step1
Open the Input/Output Monitor
screen.
Step2
Press the [F1] (Details) key.
The "Input/Output Details" screen then
displays.
"SI MONITOR 1 DETAIL" screen
Step3
Changing the port number.
Changing the tens digit of port number
Pressing the MONITOR key changes the
tens digit of the port number in the order
of 0
10
20.
Changing the ones digit of port number
Use the cursor key to select [
] or [ ] ,
then press the [enter] key. The port
number can then be changed.
Press the [ESC] key to end the monitor
display.
* There are no displays for SIW and SOW details.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SCARA Robots YRCX Series and is the answer not in the manual?

Omron SCARA Robots YRCX Series Specifications

General IconGeneral
BrandOmron
ModelSCARA Robots YRCX Series
CategoryRecording Equipment
LanguageEnglish

Related product manuals