2-4
STOPPING THE GENSET
Turn off air conditioners and other large appliances
and let the genset run for two minutes to cool down
before stopping. This reduces backfiring and run-
on. Then press the switch to STOP to stop the gen-
set.
RESTARTING THE GENSET
See Section 11. Troubleshooting if the genset shuts
down abnormally.
ENGINE ONLY OPERATION
(HGJAD, HGJAE, HGJAF only) – Shutdowns due to
generator failure are bypassed when the genset is
restarted within one (1) minute. While operating in
this mode, the status indicator lamp flashes at a high
frequency. This feature allows the engine to run so
that hydraulic systems powered by the engine can
be operated though AC output has failed.
GENSET LOCKOUT SWITCH
(HGJAD, HGJAE, HGJAF only) – The vehicle may
be equipped with a genset lockout switch in the cab
and/or boom bucket that can be used to prevent un-
authorized starting of the genset. The switch(s)
must be in their unlocked positions to start the gen-
set.