Accumulation Check
1. In weighing mode, press TOTAL key to enter accumulation checking mode
2. Press the UNIT WEIGHT key to save and go back to normal weighing mode
3. Press CE key to clear the number of counts
PLU Count
1. In counting mode (when unit weight is present), press PLU key.
1. Enter PLU value and press M+ to confirm and save.
2. Press PLU or UNIT WEIGHT key to exit PLU mode.
2. In weighing mode, press PLU key.
1. Press PLU key again to get the corresponding unit weight
2. Counting mode is now entered
3. In PLU mode (when the right arrow symbol of PLU appears), press CE key to
enter the deletion mode of PLU value.
1. Press the M+ to confirm deletion and deletion mode of PLU is exited.
2. Press the UNIT WEIGHT key to cancel deletion; Go back to PLU mode.
User Settings
In weighing mode, press both the CE and ZERO key to go into user setting mode.
Anti-Shake
Enter the user setting mode, and press M+ until you see “FILT?”.
Press ZERO or TARE to select the filter value. The higher the value (1-6) the
higher the stability but the slower the responding speed.
Press M+ key to confirm the revised value or press the UNIT WEIGHT key to
cancel the changes.
Stable Range
Values from 0 to 6
Stable speed increases as set value increases
Factory default is 2
Enter the user setting mode, and press M+ until you see “STAB?”.
Press ZERO or TARE key to select the stable range value
Press M+ key to confirm the revised value or press the UNIT WEIGHT key to
cancel the changes.