59
• The operation mode judging temperature and standard setting temperature can be increased by 2°C
permanently, by open the circuit of JX03 at indoor unit’s printed circuit board.
13.5 Indoor Fan Speed Control
• Indoor fan speed can be set using remote control.
13.5.1 Fan Speed Rotation Chart
Fan Speed (rpm) CS-A9PKD CS-A12PKD
SHi 1060 1100
Hi 1020 1080
Me 850 930
HLo 750 820
CLo 710 780
Lo- 670 740
SLo 650 720
SSLo 300 300
QSHi 990 1030
QHi 950 1010
QMe 780 860
QHLo 680 750
QLo 640 710
Speed CS-A18PKD CS-A24PKD CS-A28PKD
SHi 1310 1530 1520
Hi 1240 1390 1470
Me 1100 1220 1320
HLo 1060 1180 1270
CLo 1000 1100 1200
Lo- 820 910 990
SLo 630 700 780
SSLo 300 300 300
QSHi 1220 1440 1430
QHi 1150 1300 1380
QMe 1010 1130 1230
QHLo 970 1090 1180
QLo 910 1010 1110