User Manual - Typhoon Open 01/2018 edition
.
PARAMINA SA Byway Evaggelistrias str. 19300 Aspropirgos, Greece, Tel: 0030 210 5575860-1
Fax: 0030 210 5575868, email: service@paramina.gr - website: www.paramina-compressors.com
13
Cylinder filling procedure
Make sure that filling hoses as well as threads are in perfect condition without cracks or breaks.
Filling hose connectors should be connected on the cylinder without the use of tools. Sealing is achieved with o-ring
and internal pressure.
A. Filling hose connectors used for filling cylinders up to 232 bar are divided in two categories:
Filling Connector according to DIN 200
INTERNATIONAL / ‘’A’’ Clamp Adaptor
B. For cylinders filling at 330 bar, only the use of filling connectors according to DIN 300 (different adaptor
than the one at DIN 200 bar) is allowed.
Use cylinders that correspond to the pressures produced by the compressor. All the using filling cylinders
must be in accordance with international standards and directives. They must have the corresponding mark
(symbol and technical data) at its neck and a valid hydraulic overpressure certificate test. Cylinder valve has to be
DIN200 or DIN300 (according to EN 144-2).
Check the cylinder safety pressure (232 or 330 bar for example) so as to correspond to the preset final pressure of
the compressor.
Connect the cylinder, having the filling hose connector’s valve and the cylinder’s valve turned off, and start the
compressor by pressing the Start button.
Then, first turn on the filling hose connector’s valve and then the one of the cylinder.
200bar filling
DIN 200 filling connector
(Only up to 232 bar)
DIN 300 filling connector
(ATTENTION: longer adaptor)
(Up to 330 bar)
INTERNATIONAL
/ ‘’A’’ Clamp Adaptor
(Only up to 232 bar)