Trouble Shooting
CAUTION
Before any maintenance work on the compressor, make sure there is not air inside, under pressure.
Every time you stop the compressor, ALWAYS open the manual drains so as to remove condensate.
Maintenance work on the compressor must always be done with the compressor stopped and disconnected from
the mains supply. Never forget to open the manual drains, after stopping the compressor.
Especially when you are planning to clean the solenoid valves (auto drains version), always turn off the main
electrical supply.
You must always have in mind, if you disconnect the coil of the solenoid valves, without turning off the electrical
supply, it will be destroyed immediately!!!
Trouble
Cause
Remedy
Motor does not start
Electric circuitry faulty
Check power supply fuses or/and
compressor fuses, terminal
connections, wire leads.
Thermal switch enabled
Decreased
performance of the
compressor
1.Blocked air intake filter
1.Clean - Replace
2.1
st
stage, 2
nd
stage or 3
rd
stage valves,
are not properly closed
2.Check the intermediate pressures
3.1
st
stage, 2
nd
stage or 3
rd
stage Piston
rings worn
3.Replace
4.Worn cylinders
4.Replace
5.Pipes leaking
5.Tighten and reseal
6.Solenoid valves stuck open
6.Clean - Replace
7.Unstable power supply - voltage
7. Check power supply fuse box
8.Wrong cable diameter or long cable
8.Check - Replace
9.Interstage safety valves leaking
9.Check - Replace
Compressor does not
attain final pressure
1.Condensate drain Valve and / or fittings
leaking
1.Tighten and reseal
2.Premature opening of final safety valve
2.Clean final safety valve and readjust
3. Excessive piston clearance
3. Replace and regulate again
4. Final Safety valve’s safety lock opens
prematurely
4. Check the intermediate pressures,
regulate or replace valves
5.Interstage safety valves leaking
5.Check - Replace
6.Final stage piston rings worn
9.Check - Replace
Interstage Safety
valves releasing
pressure
1.If the 1
st
stage safety valve is released,
the 2
nd
stage valves do not close properly
1.Check replace valves
2.If the 2
nd
stage safety valve is released,
the 3
rd
stage valves do not close properly
2.Check replace valves