Maintenance Calendar
Change Coalescing pre-filter
Every Day Check: the general condition of the compressor, Oil Level, all connections for leakage, for
unconventional operation, the auto drains and the color of condensates
1. We recommend you to calibrate compressors manometers each year or according to:
i. Compressor’s yearly operation hours.
ii. The application in which compressor operates.
2. Interstage & Final stage condensate separator lifetime is 20 years. Hydraulic Overpressure test, every 5
years.
3. BA Filter’s housing lifetime is 20 years. Hydraulic Overpressure test, every 5 years.