13
INTELLIFLO
®
Variable Speed Pump Installation and User’s Guide
12
INTELLIFLO
®
Variable Speed Pump Installation and User’s Guide
Set Speeds in Manual Mode
(Speeds 1-4 Only)
1. Press Menu.
2. Use Up or Down arrows to scroll to “Speed 1-8”,
then press Select.
3. Use Up or Down arrows to find the speed (1-4) you
wish to program, then press Select.
4. Speeds 1-2 default setting is Manual. Speeds
3-4 default setting is Egg Timer. To set a speed in
Manual mode, press the Down arrow (“Set Speed”
will display) and press Select to change. Use the
Up or Down arrow to adjust speed.
5. Press Save to save the new speed setting.
Set Speeds in Egg-Timer Mode
(Speeds 1-4 Only)
1. Press Menu.
2. Use Up or Down arrows to scroll to "Speed 1-8",
the press Select.
3. Use Up or Down arrow to find the speed (1-4) you
wish to program, then press Select.
4. Use the Up or Down arrows to scroll to "Egg-
Timer", then press Select.
5. To set a speed in Egg-Timer mode, press the
Down arrow ("Set Speed" will display) and press
Select to change. Use the Up or Down arrow to
adjust speed.
6. Press Save to save the new speed setting.
7. Now press the Down arrow ("Set Time" will
display) and press Select to change. Use the Up
or Down arrows to adjust the time.
8. Press Save to save the new time setting.
Manual Mode Menu Screen Egg Timer Menu Screen
12:15p
Manual
12:15p
Egg Timer
Time
Set Speed
Pump Menu: Speeds 1-8
SPEED 1-8
Speed 1 (1-4)
Manual
Schedule
Egg Timer
Set Speed - Default: MANUAL
Set Speed
Set Start Time
Set Stop Time
Set Speed
Time
Speed 5 (5-8)
Schedule
Set Speed
Set Start Time
Set Stop Time
Disabled
Default: Disabled
MENU
Set Speeds 1-8 in Schedule Mode
In Schedule mode, Speeds 1-8 can be programmed
to run a certain speed at a certain time of day. To run
a scheduled speed, press Start/Stop. The screen will
display “Running Schedules” when it is ready to run
a scheduled speed. If Start/Stop is pressed while a
scheduled speed is running, the pump will stop running
the scheduled speed. The pump will not continue to
run the scheduled speed until the Start/Stop button is
pressed again.
1. Press Menu.
2. Use Up or Down arrows to scroll to “Speed 1-8”,
then press Select.
3. Use Up or Down arrows and press Select for the
speed you wish to set and schedule.
4. Press Select (display will be highlighted) and scroll
to “Schedule”.
5. Press Save.
6. Press Down arrow (“Set Speed” will display) and
press Select to change. Use the Up or Down
arrow to adjust speed.
7. Press Save to save the new speed.
8. Press the Down arrow again, “Set Start Time” will
display. Press Select - the cursor will highlight the
minute column.
9. Use the Up or Down arrow to change the time
and the Left or Right arrow to move cursor from
minutes to hours.
10. Press Save to save the new start time setting.
11. Press Down arrow - “Set Stop Time” will display. Press
Select. Repeat Steps 8-9 to set stop time.
12. Press Save to save the new stop time setting.
13. Press Start/Stop.
The IntelliFlo
®
Variable Speed Pump will prime and
begin to run the programmed schedule at the specified
start time.
When running in Schedule or Egg Timer mode, the
countdown time (T 00:01) showing the hours and
minutes remaining is displayed.