API Functions36
Copyright © 2006–2016 Pico Technology Ltd. All rights reserved.ps2000pg.en r11
5.20
ps2000SetAdvTriggerChannelConditions
int16_t ps2000SetAdvTriggerChannelConditions
(
int16_t handle,
PS2000_TRIGGER_CONDITIONS *conditions,
int16_t nConditions
)
This function sets up trigger conditions on the scope's inputs. The trigger is defined by
a PS2000_TRIGGER_CONDITIONS structure.
Applicability
Available in block mode and fast streaming mode only
PicoScope 2202, 2204, 2204A, 2205 and 2205A only
Arguments
handle: the handle of the required oscilloscope
conditions: a pointer to a PS2000_TRIGGER_CONDITIONS
structure specifying the conditions that should be applied to the
current trigger channel. If NULL, triggering is switched off.
nConditions: should be set to 1 if conditions is non-null,
otherwise 0
Returns
0: if unsuccessful, or if one or more of the arguments are out of
range
non-zero: if successful

Other manuals for pico Technology PicoScope 2200A Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the pico Technology PicoScope 2200A Series and is the answer not in the manual?

pico Technology PicoScope 2200A Series Specifications

General IconGeneral
Brandpico Technology
ModelPicoScope 2200A Series
CategoryTest Equipment
LanguageEnglish

Related product manuals