FUEL
SYSTEM/CARBURETION
Testing
Accelerator
Pump
Testing
On
models
equipped
with
an
accelerator
pump,
verify
proper
accelerator
pump
operation
use
the
following
proce
dure:
Wear
eye
protection
when
performing
this
procedure.
1.
Turn
engine
off.
2.
Remove
air
intake
silencer.
3.
While
observing
pump
outlet
nozzle
in
carburetor
quickly
open
throttle.
A
steady
stream
of
fuel
should
be
evident
from
each
carburetor
accelerator
pump
outlet
nozzle
as
the
throttle
is
opened.
The
pump
reservoir
must
be
full
of
fuel
before
performing
this
test.
After
operating
the
accelerator
pump
two
or
three
times
the
reservoir
will
be
empty
and
fuel
will
no
longer
spray
from
the
nozzle
until
the
engine
is
started.
Some
causes
of
improper
pump
operation
are:
No
fuel
entering
chamber
Worn
pump
cam
Diaphragm
damaged
or
swollen
Check
valve
in
nozzle
stuck
open
or
closed
Outlet
nozzle
restricted
Passages
or
hoses
restricted
Troubleshooting
Refer
to
Troubleshooting
at
the
end
of
Maintenance
section
for
carburetion
troubleshooting
information.
Polaris
Sales
Inc.
3.47
3/00

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polaris Virage TX 2000 and is the answer not in the manual?

Polaris Virage TX 2000 Specifications

General IconGeneral
BrandPolaris
ModelVirage TX 2000
CategoryBoat
LanguageEnglish

Related product manuals