8. Fault Displays
8.1 Wireless Mismatch
If an input is assigned as a type (Final exit, Intruder, etc) but no
wireless detector has not been learnt on that input number or vice
versa, this fault will be displayed.
8.2 Wireless Tamper
If a wireless input is in tamper, the alarm will activate and the input
in fault will be displayed.
8.3 Battery Low
The Enforcer 32-WE monitors the batteries of each wireless device and is defined by the following
displays:
Battery Low UXX (U = Keyfobs. XX = User Number)
Battery Low IXX (I = Inputs. XX = Input Number)
Battery Low BXX (B = Bell. XX = Bell Number)
If battery low is displayed it is advisable to replace the battery within 28 days of this message being
shown.
8.4 Wireless Supervision
The Enforcer 32-WE monitors the operation of each wireless device
and is defined by the following:
Radio Supervision IXX (I = Input, XX = Input Number)
Radio Supervision BXX (B = Bell, XX = Bell Number)
If this occurs it would be advisable to check the signal strength of the device in the diagnostics
function.
8.5 Jamming
This is reported when a jamming signal is recognised on the
wireless frequency.
Check that no wireless interference is in close proximity to the radio
devices/panel.
8.6 Wireless Poll Fault
This is displayed when no ‘polls’ are received for 20 minutes before
the set operation. Test the signal strength / battery on each
wireless device.
Wirls mismatch
Input 01
Alarm Silenced
Input 01
User
Battery Low V05
Input 02
Wirls Supervn F1
Office
Wireles Jam WZm
Input 01
Wirls Poll F700