EasyManuals Logo
Home>Pyronix>Security System>Enforcer 32-WE

Pyronix Enforcer 32-WE Programming And Installation Manual

Pyronix Enforcer 32-WE
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
Enforcer Programming Manual
Page: 10
4.3 Install ZEMs
The Enforcer 32-WE supports up to 66 inputs. This is mapped by 32 wireless inputs and 34 wired
inputs.
4.3.1 ZEM Address
[0] ZEM Address 0 (Inputs 35-42) [1] ZEM Address 1 (Inputs 43-50)
[2] ZEM Address 2 (Inputs 51-58) [3] ZEM Address 3 (Inputs 59-66)
NOTE: Inputs 33 and 34 are taken from the I/O board, this does not need to be addressed.
4.3.2 ZEM Installed
[0] No [1] ZEM8 / EURO37R (see page: 39)
4.3.3 Enter Location
The text entered here will be displayed on the LCD display if a fault occurs on the ZEM, so the
ZEM can be easily located or referenced. For example, the location text maybe "ZEM Kitchen",
"ZEM Loft" etc.
Install ZEMS Programming
1. Press or to scroll to 'INSTALL ZEMS'. Press
.
2. Press [ or ] to select the 'ZEM Address' . Press
.
3. Press [ or ] to select the 'ZEM8 or EURO37R' or
No' to 'ZEM Installed'. Press .
4. Enter the location of the ZEM. This is so it is
referenced and will appear on the display if a fault
occurs. Press to return to ZEM addressing.
5. Press to return to the Engineers menu.
4.4 Wireless Device Control
The Enforcer 32-WE supports a maximum of 32 wireless inputs, 32 wireless keyfobs and 2 wireless
Deltabell external sounders.
4.4.1 Control Inputs
'Control Inputs' learns and deletes wireless inputs.
4.4.2 Control Bells
'Control Bells' learns and deletes wireless Deltabell external sounders.
4.4.3 Programming Keyfob Buttons
'Program Keyfob Buttons' assigns actions to each buttons on the keyfob.
NOTE: Keyfobs are learnt in the Master Manager Menu in the function 'CHANGE CODES'. Refer to
the user manual (RINS1548).
[0] No action: Disables the button [1] Show Status: GREEN = Unset. RED = Set.
[2] Set Area: Sets the chosen area [3] Unset Any Area: Unsets any area on the system
[4] Latch Output: Latches an output (programmable) when the nominated button is pressed.
[5] Timed Output: Activates an output for a period of time (programmable in seconds)
[6] Personal attack: Activates a personal attack activation (programmed in Engineers only)
INSTALL ZEMS?
ZEM Address
[0]
ZEM Installed
No [0]
Enter Location
_

Table of Contents

Other manuals for Pyronix Enforcer 32-WE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix Enforcer 32-WE and is the answer not in the manual?

Pyronix Enforcer 32-WE Specifications

General IconGeneral
BrandPyronix
ModelEnforcer 32-WE
CategorySecurity System
LanguageEnglish

Related product manuals