Page: 33
Dial Out Menu Programming:
1. Press or to scroll to 'DIAL OUT MENU'. Press .
2. 'Select PC to dial' will be displayed. Enter the PC number to dial out
to and press .
3. 'Select Operation' will be displayed. Use [ or ] to select the
operation and press the PC will be dialed.
4. Press to return to the Engineer menu.
4.24 Clean Start
It is recommended that a factory default (Clean Start) is performed after initial power up to ensure
that the correct defaults are applied. Please see page: 44 for a list of all defaults for each code.
4.24.1 Clear Wireless Data
If this function is not accepted, then all wireless inputs, wireless external sounders will be still
present on the Enforcer 32-WE.
4.24.2 Clear Codes
If this function is not accepted, then all codes, tags and keyfobs will be still present on the
Enforcer 32-WE.
4.24.3 Clear Logs
If this function is not accepted, then all event logs will be still present on the Enforcer 32-WE.
NOTE: If everything is defaulted, the system memory will also be restored to factory defaults
except the following:
Keypad address '0' remains enabled at all times & the keypad in use remains enabled
Additional keypads connected will keep the area information
Clean Start Programming
1. Press or keys to scroll to 'CLEAN START'.
Press .
2. a) Enter the default code 2000 for Ungraded
defaults
3. b) Enter the default code 2020 for PD6662 EN
Grade 2 defaults.
4. 'CLEAR WIRELESS DATA' will be displayed. To delete
all wireless data (any inputs and bells that are
learned) press , or press to keep the
wireless data.
5. 'CLEAR CODES' will be displayed. To delete/default
all user code, tag and keyfob data, press , or
press to keep the codes that are programmed.
6. 'CLEAR LOGS' will be displayed. To delete all event
log data press , or press to keep the event
log data.
DIAL OUT MENU?
Select PC to
dial [1]
Select Operation
Connect to PC[0]
CLEAN START?
CLEAN START?
[ ]
Please Wait
Panel has been
clean started!
Cl’r Wirls Data?