Enforcer Programming Manual
Page: 18
Exit Modes Programming
1. Press or to scroll to 'EXIT MODES'. Press .
2. 'A Exit Mode' will be displayed. Press [ or ] to select the Exit
Mode and press . Repeat for all areas.
3. Press to return to the Engineer menu.
4.11 Change Codes
This function changes the Engineer code, the Master Manager code and adds/changes/deletes any
Duress or Guard codes.
Default Codes: User: 1234. Master Manager: 2222. Engineer: 1111
NOTE: User codes, fobs and keyfobs can only be changed in The Master Manager Menu. Please see
the user manual for more information.
4.11.1 5 Digit Pins?
If enabled, a 5 or 6 digit code will automatically block several possible 4 digit codes that clash
with it.
4.11.2 Change Duress Codes
[2] Duress Code: If the Enforcer 32-WE is unset using a 'Duress' code, a silent 'Duress' or 'Hold
Up' signal is sent.
NOTE: ACPO policy prevents use of Duress codes for police call purposes.
[3] Guard Code: A 'Guard code' can be used to unset the Enforcer 32-WE only after an alarm
has been activated for a minimum time (see 'Change Timer' Appendix C, page 50). The code will
set a system and an output type is available to signal when this code is used (00058 Guard
Code).
[4] Dial Out: If a dial out code is programmed and entered when the Enforcer 32-WE is unset,
the PC number 1 that is programmed (see 'SET UP DOWNLOADING' on page: 28) will be dialled.
4.11.3 Change Master Manager Code
The Master Manager code can be 4, 5 or 6 digits long, or can be assigned to a tag. It may also
have the following functions:
[0] Unset / Set. [1] Unset Only. [2] Set Only. [3] None (used only to access the menu).
Flexi Set: If enabled, the default area the device is assigned to, will set. If disabled, the default
area will be shown on the display, and from here other areas can be selected.
Wards/Access: This will only be displayed if an Entry Control or Access Control reader is
installed on the system. If the address of the Entry Control or Access Control device is entered
here, then the code will be assigned to that reader only.
4.11.4 Change Engineer Code
The Engineer code can be 4, 5 or 6 digits long.
Change Codes Programming
1. Press or to scroll to 'CHANGE CODES'. Press .
2. '5 Digit Pins' will be displayed. Press [ or ] to enable or disable
and press .
3. 'Change Duress Codes' will be displayed. Press to add any
Duress, Guard or Dial out codes (as described previously) or press
.
4. 'Change Master Manager Code' will be displayed. Press to
change the Master Manager code or press .
5. 'Change Engineer Code' will be displayed. Press to change the
Engineer code or press to return to the Engineer menu.
EXIT MODES?
A Exit Mode
Final Door [1]
CHANGE CODES?
5 Digit Pins?
No [0]
Change Duress
Codes?
Change Master
Manager Code?
Change Engineer
Code?

Table of Contents

Other manuals for Pyronix Enforcer 32-WE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix Enforcer 32-WE and is the answer not in the manual?

Pyronix Enforcer 32-WE Specifications

General IconGeneral
BrandPyronix
ModelEnforcer 32-WE
CategorySecurity System
LanguageEnglish

Related product manuals