and the PC be called. Once answered, both the Enforcer 32-WE and the software will hang up.
After a few seconds the Enforcer 32-WE will call the software and connect.
4.21.3 Telecom Line
[0] Dedicated Line: When the software dials the Enforcer 32-WE, it will answer immediately.
[1] Shared Line: When the software dials the Enforcer 32-WE, it will hang up after the primed
number of rings. The software will then redial the Enforcer for it to answer in its primed state.
4.21.4 Number of Rings to Prime
[01]-[15] = This is the number of rings (audibile ‘rings’ in the phone call) to prime the Enforcer
32-WE when the Enforcer is installed on a shared telephone line (see ‘Shared Line’ above).
4.21.5 Roving Dial
This option (when set to 'No') prevents anyone dialling into the panel using roving dial from the
software. To comply with DD263:2010 this option must be defaulted to 'No'.
4.21.6 Modem Speed
For future use. Make sure this is set to [1] HIGH.
4.21.7 Prefix Tel No
If, for example a '9' is required to dial an ‘outside’ line, this must be entered here.
4.21.8 ARM PC Telephone Number
This is the phone number of the PC modem where the software is installed for performing the
'Automatic Remote Maintenance' (ARM) service. Press a button to add any symbols: ‘,’ = 2
second pause, ‘+’ for roaming calls. This is used in conjunction with the ‘DIAL OUT MENU’
function (see page: 32).
4.21.9 Program PCs
Up to 4 x PC modem numbers may be programmed, i.e. the software maybe installed on four
different PCs (office PC, home PC, etc). These are selected in the 'Dial Out Menu' in the Master
Manager menu (refer the Enforcer 32-WE User manual).
The signalling events are unique to each PC modem number.
Send Alarms: If enabled, the panel will report ‘alarm’ events to the PC running UDL software.
Send Faults: If enabled, the panel will report any ‘fault’ events to the PC running UDL software.
Send Set / Unset: If enabled, the panel will report ‘open/close’ (arm/disarm) events to the PC
running UDL software.
Send Access Control: If enabled, the Enforcer 32-WE will report any ‘access control’ events to
the PC running UDL software.
4.21.10 UDL Password
This password is used to identify the UDL connection. Make sure the password here and on the
software are the same.
4.21.11 Redials
The number of redials that it will call to the software before it fails.
Set Up Downloading Programming
1. Press or to scroll to 'SET UP DOWNLOADING'. Press .
2. 'Download by' will be displayed. Use [ or ] to scroll through
the different options and press to select.
3. 'Security Mode' will be displayed. Use [ or ] to scroll through
the different options and press to select.
4. 'Telecom Line' will be displayed. Use [ or ] to scroll through
the different options and press to select.
5. 'Number of Rings to Prime' will be displayed. Enter the number of
rings and press .
6. 'Roving Dial' will be displayed. Use [ or ] to enable or disable
the roving dial. Press .
7. 'Modem Speed' will be displayed. DO NOT ALTER. Press .
SET UP
DOWNLOADING?
Download by
Modem [1]
Security Mode
Auto-Answer [0]
Telecom Line
Dedicated [0]

Table of Contents

Other manuals for Pyronix Enforcer 32-WE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix Enforcer 32-WE and is the answer not in the manual?

Pyronix Enforcer 32-WE Specifications

General IconGeneral
BrandPyronix
ModelEnforcer 32-WE
CategorySecurity System
LanguageEnglish

Related product manuals